Automatic Power Factor Controllers

We offer our clients with automatic power factor controller which provide cost effective solution to the control of power factor in installations. These controllers can be programmed to suit the requirements of the user. The cutting edge technology is being implemented in the production process to ensure excellent performance and longer life of these controllers. Our range includes power factor controller, automatic power factor controller, compact power factor controller, automatic power factor controller type 1188, automatic power factor controller type 1143, automatic power factor controller type 1179, automatic power factor controller type 1107 and three phase(3-c.t) automatic power factor controller- type 2205.

View Enquiry Basket

Automatic Power Factor Controller Type 1188

Automatic Power Factor Controller Type 1188

These automatic power factor controller type 1188 provide cost effective solution to the control of Power Factor in smaller installations. These automatic power factor controller type 1188 are available for a variety of applications, the Controllers can be programmed to suit the User needs. The Controllers are housed in 96 X 96 DIN flush mounting enclosure with behind the panel depth of only 70mm. 1188 / 2 step is useful to compensate the Power Factor of major on /off loads such as compressors. It is also useful for correcting the Power Factor on the secondary of a Utility Supply Transformer (usually pole mounted), by means of two unequal capacitors used for the two stages, to take care of load variations.1188 – 4, 6 and 8 step is used as a regular Automatic Power Factor Controller. It is available for Three Phase as well as for Single Phase applications. as for Single Phase applications. The single-phase version is required for extremely unbalanced loads, where three single-phase systems are used in star connection.1188 / 4 step is available in a variety of sequences First In First Out, Binary normal timing and Binary Fast Discharge timing modes. Please ask us for details. Normally supplied is First In First Out sequence.Both models are available for thyristor switched capacitor systems. The display is 7 – segment 12/7mm bright LED display 3 digit for 1188/4step and 4 digit for the 1188 / 8 step. LED’s provide appropriate indications of lag, lead, on, off and the stages on. The display provides indication of alarm condition. The display reads 1.uuu (1.uu for 4 step) when current is very low. The displayreads 2.uuu (2.uu for 4 step) when your external connections are wrong. There are no settings to make. The Controller limits are factory programmed. The Controller is designed to provide the best possible Power Factor under the system constraints.

  • Field proven design
  • Most Economical APFC Relay available in market.
  • No settings to make.
  • Compact DIN Std Flush Mounting 96 X 96mm Case.
  • Depth behind panel = 70mm.
  • Sensitivity better than 1 % (50 mA).
  • Built in software timers for fast correction yet ensuring capacitors safety.
  • Reliable COSROBOTTM technology.
  • Available in 2, 4, 6 and 8 stages.
  • Special versions available for Thyristor Real time control
  • Choice of Sequences - FIFO or BINARY (factory set)
  • Auto detection & indication of external wrong connections
  • Auto detection & indication of low load current.
  • Built in Syntron Reliability
Specifications: Voltage: 380 to 470 Volts three-phase AC for voltage sensing. (100 to 270 Volts for single-phase version)110 V PT operated versions available for HT application. Aux Voltage: 210 to 260 Volts single-phase AC 50 Hz as Auxiliary supply. (110 V version also available. Current: Through secondary of CT on Y phase 0.05 Amps to 5 Amps. Limits: The capacitors are switched on sequentially whenever the Power Factor drops to or below 0.99 Lag. The capacitors are switched off sequentially when the Power Factor goes to or above 0.99 lead. Timing: For First In First Out Sequence and Normal Binary Sequence: Timing between stages on or off is 6 seconds. A capacitor once switched off is not switched on for 60 seconds to allow it to discharge fully. Timing: For Fast Discharge Binary Sequence: Timing between stages on or off is 6 seconds. This timing includes the time required for the capacitor to be force discharged. Timing: For thyristor controlled capacitors: Timing between stages on or off is 1 second. Contacts: Each stage is provided with one Normally Open (NO) contact rated for maxima of 230 Volts and 5 Amps AC resistive load. Weight: 1 Kg approx. Size: 96 X 96 X 70mm (panel cutout 92 X92mm)

Add to Enquiry Basket

Automatic Power Factor Controller Type 1143

The Syntron automatic power factor control relay type 1143 is specially designed to provide accurate and reliable control of power factor of an electrical installation 1143 has micro controller technology. This is a Syntron exclusive trademarked as COSROBOTTM. COSROBOTTM technology evolved at Syntron specifically for use in APFCRs where the problems of electrical noise, transients etc. are accentuated, and normal microprocessor technology fails under such conditions. COSROBOTTM 1143 is now more reliable and easier to troubleshoot. Operationally the COSROBOTTM APFCR 1143 is identical to the previous IC based version for compatibility with older panels. Some features, not available with IC based APFCRs, are provided additionally in 1143:

1 Some users, with peculiarly configured systems used to find it difficult to use Syntron automatic power factor control relay type 1143 with the Low Current Cutout set at 20%. Low Current Cutout is now reduced to 5% to accommodate such systems.

2 Some users demand timing between stages different from our standard. This modification is needed for thyristor controlled capacitors, windmills etc. This timing can now be factory set at a value from 0.2 seconds to 25 seconds.

3 The First In First Out sequence now comes with built in software timers - one for each stage - so that the APFCR waits only if the next needed capacitor is still discharging, otherwise it is switched on immediately.

4
Any other sequence such as 1+2+2+….., 1+2+4+8+…etc. are also given,factory programmed as per order. 5 There are two alarm conditions that are directly displayed Current Low (the display reads 1uuu) and Wrong Wiring (the display reads 2uuu). This condition is detected if your wiring of the APFCR is wrong, and will persist till you correctly wire the APFCR into the system.

  • Field proven design
  • Compact DIN Std Flush Mounting 144X144 Case
  • 4 Digit Digital Power Factor Meter for accurate measurement
  • Built in Auto-Manual Control
  • Built in Low Current Cutout at 5% Factory set at 0% if required
  • Calibrated PF Setting and Dead Band Dials
  • Built in Test Facility
  • Reliable COSROBOTTM technology. Auto detection of external wrong connections
  • Operationally Compatible with Syntron Types 1107 and 1125
  • Built in Syntron Reliability

Specifications: Voltage: 400 415 440 V(specify one) three phase three wire 50Hz nominal. 110V three phase versions available on request. Current: Through CT on the Main Incomer. 1 Amp or 5 Amp secondary. Low Current Cutout:Factory set at 5% (0.25 Amps for 5 Amps and 50mA for 1 Amp.) Display reads 1.uuu when the current is too low. Wrong Connections:Three voltage wires and two wires from the CT on the main incomer connect the APFCR in the electrical system. The wiring must made Correctly. The APFCR switches off all stages and displays 2.uuu to warn the operator. This condition persist till correct connections are are made. Meter: 4 digit Digital Meter : Range : 0.000 lag 1.000 0.000 lead. PF Setting Range: 0.75 Lag to 0.99 Lead. Dead Band Control: 4 deg. to 14 deg. electrical. Capacitor Switching: Standard Models are available for 4, 6, 8, 10, 12, 14 & 16 stages, with the sequence of First In First Out or First In Last Out. (Specify one) other sequences on request. Contact Rating: Each contact is rated for maxima of 230V, 5 Amps AC resistive loads. Dimensions: Front Bezel : 144mm x 144 mm. Panel Cutout : 138mm x 138 mm. Depth Behind Panel : 100mm, including terminals. Weight: Front Bezel : Approx 2 Kg.

Add to Enquiry Basket

Automatic Power Factor Controller Type 1143

Automatic Power Factor Controller Type 1179

Automatic Power Factor Controller Type 1179

The Syntron Truly Intelligent automatic power factor controller type 1179 is specially designed to provide accurate and reliable control of Power Factor of an electrical installation. 1179 has Microcontroller technology. This is a Syntron exclusive trademarked as COSROBOTTM. This technology evolved at Syntron specifically for us ein APFCRs where the problems of electrical noise, transients etc, Are accentuated, and normal microprocessor technology fails under such condition.

  • Field proven design
  • 4 Digit Digital Power Factor Meter for accurate measurement.
  • Built in software timers for fast correction yet ensuring capacitor safety.
  • Reliable COSROBOTTM Technology. Available in 4, 6, 8, and 10 stage models.
  • Special Versions available for thyristor real time control.
  • Built in Syntron reliability.
  • Special Alarm control provided for wrong external connection, insufficient capacitors etc.
  • Compact DIN Std Flush Mounting 144 X 144 X 100mm Case.
  • Sensitivity better than 1% (50 Milli AMPs)
  • No setttings to make.
  • Self learning. No site programming.
  • Truly intelligent Kvar based system for perfect control.
  • Equalizes the duty cycles on same value Capacitors.
  • Measures Kvar of each stage automatically.
  • Built in Syntron Reliability.
  • Special versions available for 'fast discharge' capacitors.
Function: When switched on first, the 1179 measures it’s environment, and tells the user if there is anything wrong. Thus if the load current is extremely low (below about 0.5%) it gives a different display, if your connections are not correct, it gives an alarm, etc. Each stage of the 1179 has a corresponding software timer in memory. Thus whenever a stage is switched off the times begins counting 60 seconds, 1179 then does not switch it on even if needed, because that capacitor is charged, and re-switching it would ruin it on transients. 1179 then re-calulates and switches on other combination that will do the job. However the capacitor is used immediately after the timing is over. Manual Control of the 1179 is also unique. Specifications: Voltage : 400-440 V (specify one) three phase three wire 50 Hz nominal : 110V three phase versions available on request. Current : Through CT on the Main Incomer. 1 Amp or 5 Amp secondary. Low Current Cutout : Factory set at 1%. Display reads 1. uuu when the current is too low. Wrong Connections : Three voltage wires and two wires from the CT on the main incomer connect the APFCR in the electrical system. The wiring must be made correctly. The APFCR switches off all stages and displays 2.uuu to warn the operator. This condition persists till correct connections are made. Meter: 4 digit Digital Meter:Range:0.000 lag – 1.000 – 0.000 lead. PF Setting Range : The controller being intelligent, you have no setting to make. It provides the best possible power factor under the system constraints. Capacitor Swithing : Standard Models are for 4,6,8 and 10 stages, The capacitors are switched in reverse order of their size after calculating the requirements, i.e. the largest one in the chosen group is switched on first. The capacitors are switched off in the order of their size, i.e. the smallest capacitor is switched off first. Contact Rating : Each contact is rated for maxima of 230 V, 5 Amps AC resistive loads. Provide a 2Amps fuse in the Common terminal, higher rating fuse will cause damage to controller in case of a fault in the contactor system. Dimension: Front Bezel : 144mm X 144mm. : Panel Cutout: 138mm X 138mm. : Depth Behind Panel: 100mm, including terminals. Weight: Approx 2 kg.

Add to Enquiry Basket

Automatic Power Factor Controller Type 1107

Power Factor is an important parameter needing control. The Syntron automatic power factor control relay type 1107 is specifically designed to control the power factor of an installation accurately and reliably. Introduced first in 1982, the automatic power factor control relay type 1107 has undergone countless refinements and improvement to make it the most sought after APFCR in India. The leaflet reflects all the changes, refinements and additions made in the line. The major additions are: The original 1107 had an analog power factor meter, some users demand a digital power factor meter thinking that it would be more accurate. Actually the PF meters normally provided are 2 ½ digit type, the resolution of which is worse. Accuracy may be the same. We therefore designed in a four digit power factor meter the accuracy of which is the same as analog and resolution is ten times better than the two and a half digit versions. The meter provided on the 1107 is also far more stable to provide meaningful readings.
  • Field proven since 1982.
  • Tens of thousand in use.
  • Up to 32 stages with extension sequencer.
  • Built in Auto/Manual Control.
  • Available for LT & HT application.
  • 4 Digit Power Factor Meter.
  • Dead band control to prevent hunting.
  • Up to 24 stages in standard version.
  • One of the First & Oldest APFC Relay manufactured in India.
  • High noise immunity.
  • Built in test facility.

Function: The APFCR controls the power factor of the installation by giving signals to switch on or off power factor correction capacitors. It should be noted that this is only a Relay constituting the so to say 'brain' of the system and it cannot switch the capacitors directly but need intermediate contractors of appropriate ratings. The APFCR has a built in power factor transducer which measures the power factor of the installation and converts it to a DC voltage of appropriate polarity. This is compared with a reference voltage which can be set by means of a knob calibrated in term of power factor. When the power factor falls below setting, the APFCR switches on the capacitors one by one in sequence, which can be either First In First Out (FIFO) or First in Last Out (FILO). In either case the capacitors of all stages must all be of same rating. The Relay switches them on in linear sequence Facilities: Power Factor Meter : Four Digit Digital Meter. Please refer description above. PF Setting Dial: The required PF is to be set on this dial calibrated from 0.75 lag to .99 lead Dead Band Knob: This setting determines the range of phase angle over which the Relay will not respond. Dead Band is necessary to prevent overcorrection and hunting. Undercurrent Blocking: When the load is low the effect of the capacitors is more pronounced and may lead to hunting. Undercurrent Blocking shuts down the Relay when the load is too low, and switches off all the capacitors one by one in sequence. Auto/Manual Facility : The system may be operated manually from the Relay by this control. Special Timing Sequence: The APFCR has a built in logic timer which inhibits operation for a fixed delay of 65 seconds for LT Relays (and 310 seconds for HT application Relays) whenever the following changeover occur: • Changeover from Auto to Manual and vice versa. • Changeover from capacitor off to capacitor on signal. This delay ensures that the capacitors are fully discharged before they are re switched in. This avoids transient and damage to capacitors. Indication : The APFCR has solid state indication lamps (LEDs) for every one of the function the operator should know about : Auto, Manual, Low PF, High PF, Timer, Amps OK, Test (to indicate that the Relay is in TEST Mode.) and for each capacitor switching stage.

Add to Enquiry Basket

Automatic Power Factor Controller Type 1107

Automatic Power Factor Controller- Type 2205

Automatic Power Factor Controller- Type 2205

We manufacture and export high precision and technologically advanced electronic meters, digital panel voltmeters, digital panel meters and other components. These three phase(3-C.T) automatic power factor controller- type 2205 are quite popular across industry. Our long range of satisfied clientele are from India as well as from international markets like Europe and USA. We are committed to to deliver superior quality products at competitive prices and within the scheduled time frame. Facilities: Digital Meter: Please refer description above. PF Setting Dial: The required PF is to be set on this dial calibrated from 0.75 lag to .99 lead Dead Band Knob: This setting determines the range of phase angle over which the Relay will not respond. Dead Band is necessary to prevent over correction and hunting. Undercurrent Blocking: When the load is low the effect of the capacitors is more pronounced and may lead to hunting. Undercurrent Blocking shuts down the Relay when the load is too low, and switches off all the capacitors one by one in sequence. Auto/Manual Facility: The system may be operated manually from the Relay by this control. Special Timing Sequence: The APFCR has a built in logic timer which inhibits operation for a fixed delay of 65 seconds for LT Relays (and 310 seconds for HT application Relays) whenever the following changeover occur: • Changeover from Auto to Manual and vice versa. • Changeover from capacitor off to capacitor on signal. This delay ensures that the capacitors are fully discharged before they are re switched in. This avoids transient and damage to capacitors. Indication: The APFCR has solid state indication lamps (LEDs) for every one of the function the operator should know about : Auto, Manual, Low PF, High PF, Timer, Amps OK, Test (to indicate that the Relay is in TEST Mode.) and for each capacitor switching stage.

Add to Enquiry Basket